- OROS Dynamic Real Time Signal Analyser
- Meggitt-Seismic Accelerometer
Make & Model: OR-34 and 731A
- Scientist = Rs. 1430 per hour + GST
- Technician = Rs. 715 per hour + GST
2. Charges towards utilization of
Equipment’s/Instruments will be based on cost of Equipment’s/Instruments.
3. Reporting Charges: Varies from Case to Case basis
Mr. Girish Kumar M (Scientist-D)
Email: girishkumar[at]cmti[dot]res[dot]in
Land Line: +91-80-22188390
Mr. Prakash Vinod (Scientist-F, Center Head – SMPM)
Email: prakashv[at]cmti[dot]res[dot]in
Land Line: +91-80-22188243
OROS Dynamic Real Time Signal Analyser
Make & Model: OR-34
- Scientist = Rs. 1430 per hour + GST
- Technician = Rs. 715 per hour + GST
2. Charges towards utilization of Equipment’s/Instruments will be based on cost of Equipment’s/Instruments.
3. Reporting Charges: Varies from Case to Case basis
Mr. Girish Kumar M (Scientist-D)
Email: girishkumar[at]cmti[dot]res[dot]in
Land Line: +91-80-22188390
Mr. Prakash Vinod (Scientist-F, Center Head – SMPM)
Email: prakashv[at]cmti[dot]res[dot]in
Land Line: +91-80-22188243
Scheck Horizontal Balancing Machine Make & Model: Scheck – CAB 690
- Scientist = Rs. 1430 per hour + GST
- Technician = Rs. 715 per hour + GST
2. Charges towards utilization of Equipment’s/Instruments will be based on cost of Equipment’s/Instruments.
3. Reporting Charges: Varies from Case to Case basis
Mr. Girish Kumar M (Scientist-D)
Email: girishkumar[at]cmti[dot]res[dot]in
Land Line: +91-80-22188390
Mr. Prakash Vinod (Scientist-F, Center Head SMPM)
Email: prakashv[at]cmti[dot]res[dot]in
Land Line: +91-80-22188243
Machinery Health Analyser, Accelerometer and Tachometer.
Make& Model: CSI , B& K and Monarch
- Scientist = Rs. 1430 per hour + GST
- Technician = Rs. 715 per hour + GST
2. Charges towards utilization of Equipment’s/Instruments will be based on cost of Equipment’s/Instruments.
3. Reporting Charges: Varies from Case to Case basis
Mr. Girish Kumar M (Scientist-D)
Email: girishkumar[at]cmti[dot]res[dot]in
Land Line: +91-80-22188390
Mr. Prakash Vinod (Scientist-F, Center Head – SMPM)
Email: prakashv[at]cmti[dot]res[dot]in
Land Line: +91-80-22188243
Data Acquisition System ,Impulse Hammer and Accelerometer
Make& Model: OROS, CSI and B& K
- Scientist = Rs. 1430 per hour + GST
- Technician = Rs. 715 per hour + GST
2. Charges towards utilization of Equipment’s/Instruments will be based on cost of Equipment’s/Instruments.
3. Reporting Charges: Varies from Case to Case basis
Mr. Girish Kumar M (Scientist-D)
Email: girishkumar[at]cmti[dot]res[dot]in
Land Line: +91-80-22188390
Mr. Prakash Vinod (Scientist-F, Center Head – SMPM)
Email: prakashv[at]cmti[dot]res[dot]in
Land Line: +91-80-22188243
Sound Intensity System
Make & Model: GRAS-50AI-D
- Scientist = Rs. 1430 per hour + GST
- Technician = Rs. 715 per hour + GST
2. Charges towards utilization of Equipment’s/Instruments will be based on cost of Equipment’s/Instruments.
3. Reporting Charges: Varies from Case to Case basis
Mr. Girish Kumar M (Scientist-D)
Email: girishkumar[at]cmti[dot]res[dot]in
Land Line: +91-80-22188390
Mr. Prakash Vinod (Scientist-F, Center Head – SMPM)
Email: prakashv[at]cmti[dot]res[dot]in
Land Line: +91-80-22188243
FLIR
Make& Model: T350
- Scientist = Rs. 1430 per hour + GST
- Technician = Rs. 715 per hour + GST
2. Charges towards utilization of Equipment’s/Instruments will be based on cost of Equipment’s/Instruments.
3. Reporting Charges: Varies from Case to Case basis
Mr. Girish Kumar M (Scientist-D)
Email: girishkumar[at]cmti[dot]res[dot]in
Land Line: +91-80-22188390
Mr. Prakash Vinod (Scientist-F, Center Head – SMPM)
Email: prakashv[at]cmti[dot]res[dot]in
Land Line: +91-80-22188243
Spindle Error Analyser
Make& Model: Lion Precision,USA
- Scientist = Rs. 1430 per hour + GST
- Technician = Rs. 715 per hour + GST
2. Charges towards utilization of Equipment’s/Instruments will be based on cost of Equipment’s/Instruments.
3. Reporting Charges: Varies from Case to Case basis
Mr. Girish Kumar M (Scientist-D)
Email: girishkumar[at]cmti[dot]res[dot]in
Land Line: +91-80-22188390
Mr. Prakash Vinod (Scientist-F, Center Head – SMPM)
Email: prakashv[at]cmti[dot]res[dot]in
Land Line: +91-80-22188243
Noise and Vibration Sensors
Vibration and Noise Measurements Sensors | Type and manufacturer | Specification |
Accelerometers | Uni-Axial B & K- Denmark |
Frequency Range: 1Hz to 10kHz Sensitivity: 99.43mV/g Dynamic Range:+/- 50g Peak Working Temperature Range: Application: Vibration Measurement on non-Rotating Elements. |
Tri-Axial Kistler-Switzerland |
Frequency Range: 20Hz to 10kHz Sensitivity: 10mV/g and 1000mV/g Dynamic Range: +/-500g and +/- 5g Working Temperature Range:-540C to 1200C Application: Vibration Measurement on non-Rotating Elements for a Lower Frequency Range, Like ground Vibration Measurement( |
|
Uni-Axial CSI-USA |
Frequency Range: 1Hz to 10kHz Sensitivity:100 mV/g Dynamic Range:+/- 50g Peak Working Temperature Range: Application: Vibration Measurement on non-Rotating Elements |
|
Uni-Axial Meggitt-UK |
Frequency Range: 0.1Hz to 320Hz Sensitivity:10.4 V/g Dynamic Range: 0.5g Peak Working Temperature Range:
|
|
Moicrophones (IEC 61672 Class 1) |
PCB-USA | Frequency Range: 3.75 Hz to 20kHz Sensitivity: 47.53mv/Pa Dynamic Range: 137dB Working Temperature Range: -400c to 1500C Application: Sound Pressure Level Measurement of Rotating Elements. |
Impulse force Hammer | A034703 and A034701 CSI-USA |
Frequency Range: 0 Hz to 8kHz Sensitivity: 0.23mV/N and 2.3mV/N Dynamic Range: 22200N and 2200N Application: Find the natural frequencies of components |
Sound Level Meter | 2130 B& K- Denmark |
Frequency Range: 20Hz to 20kHz Dynamic Range: 130dB Application: Overall Sound Pressure Level Measurement of Rotating Elements. |
Sound Level Calibrator | Type 42AB GRAS-France |
Precision Integrating Sound Level meters Type-0 and Type-1 as per IEC Generates 114 dB at 1000Hz |
Vibration Calibrator | Type | · Portable Handheld accelerometer calibration exciter for field calibration check of transducers · Generates 1g at 159.6Hz |
Data Acquisition System
DAQ System |
Type and manufacturer | Specification |
OROS 4 Channel Data Acquisition System |
OR-34, OROS-France |
Frequency Range: 0 Hz to 40kHz Features: 24 bit, 4 Channel Real Time Analyser ,1/3rd octave band Measurement, Data Recording and Analysing Application: Noise and Vibration Related Measurements , |
Data Physics 8 Channel Data Acquisition System |
DATA PHYSICS -USA | Frequency Range: 0 Hz to 40kHz Features: Portable, Battery operated 8 Channel with advanced noise and vibration analysis software like FFT, Waterfall, Octave, Order Tracking, Modal Analysis Software, Data Recording, Multi Analysis software. Application: Noise and Vibration Related Measurements, Modal Analysis, Operational Deflection shape and Experimental Modal Analysis. |
Sound Intensity System
SI System | Type and manufacturer |
Specification |
Sound Intensity System | OR-34, OROS-France |
Frequency Range: 0Hz to 10kHz Features: PC based Sound intensity measurement & Analysis system for Noise source Identification and ranking, Noise level contour mapping and sound power measurement Application: Sound Power Level Measurement. |
Spindle Error Analyser
SEA System |
Type and manufacturer | Features |
Spindle Error Analyser system |
CPL290 Lion Precision-USA |
Measure Spindle running accuracy and Thermal growth of Spindle at any time instant. |
Thermography System
SEA System |
Type and manufacturer | Features |
Thermography system |
FLIR | Portable, Battery Operated used in improving the machine design by experimentally evaluating heat zones, heat flow pattern and thermally induced stresses. The system should help in investigating the thermo elastic behaviour of machines. Condition monitoring of machine tools, machines, transformers, circuit breakers, motors, control panels, furnaces etc., The temperature range of camera is from 00C to 6500C. |
Dynamic Balancing Machine
SEA System |
Type and manufacturer | Features |
Dynamic Balancing Machine |
CAB 690 | Dynamic Balancing of Armatures, Spindles, Mandrel, Rotors, Propellers upto G0.4 Grades as per ISO 1940. Max Diameter |
Machinery health Analyser | 2130 CSI-USA |
CSI 2130A2 with Machinery health manager, Advanced vibration analysis, Advanced cross channel analysis, ODS (Operation Deflection shape) & Modal analysis software’s |
- Non-contact vibration measurement in the field or in the lab
- Measurement range (mm/s/V): 5, 25 and 125
- Full scale output (peak, mm/s): 20, 100 and 500
- Velocity resolution1 (μm s-1/√Hz): <0.02
- Portable, robust and reliable sensor with laser precision
- Versatile measurements from up to 22 kHz
- Variable stand-off distances from 0.09 to ca. 30 m
- Eye-safe, visible laser for easy positioning and adjustment
- Laser Type: Helium Neon (HeNe)
- Laser wavelength 633 nm, visible red laser beam
- Stand-off distance3 90 mm … ~ 30 m
Fulfils ISO 3741, ISO 3744, ISO 3745, ISO 3747 and ISO 6926 for calibrated sound power sources.
Frequency Range from 50Hz to 20kHz.
Sound Power Output 91dB re 1pW (A-weighted, 50Hz line frequency)
Comparison method for determination of sound power of noise sources according to ISO 3741.
Measurement of environmental correction, K2 according to ISO 3744.
Sound absorption measurements
Sound insulation measurements.
Low Frequency Ground Vibration Measurement, Ground Vibration Survey, Ground Vibration Measurement for Precision Metrology Equipment’s before and after the installation.
Noise and Vibration Measurements, FFT Analysis, FRF Measurement (Natural Frequency Testing), Octave Analysis (1/1, 1/3rd, 1/nth), Data Recording, Multi-Channel Multi Analysis, Run-up and Rundown Measurement, Trend Analysis, 3D Waterfall Analysis and Frequency v/s Time Map, Time Domain Analysis, Synchronous Order Tracking/Analysis, FFT Diagnostics Module, Envelop Detection. Cepstrum Analysis.
Noise and Vibration Measurement, Frequency Response Function (Natural Frequency Testing), Dynamic Balancing, Route Based Data Collection and Analysis for Condition Monitoring, Time Domain Analysis, Advanced Cross Channel Analysis, In-Situ Balancing, Order Tracking, Waterfall Diagram
Sound Pressure Level Measurement, Environmental Noise Measurement, Industrial Noise Survey, Sound Power Level Measurement as per ISO 3744 & ISO 3746
Sound pressure level measurement, Environmental Noise Measurement, Industrial Noise Survey.
- Hand-Arm Vibration Measurement (ISO 5349).
- Whole-Body Vibration Measurement (ISO 2631).
- Low-Frequency Whole-Body Vibration Measurement (ISO 2631)
Mining Industry, Process Plants, Earth Moving Machinery’s, Automobile etc
Mining, Process Plants, Earth Moving Machinery’s etc.
ORBIGate Features the following graphics and displays.
- Tabular list: Gap Voltage, Overall, Orders amplitude and phase (0.5X, 1X, nX), Sub1X, Smax.
- Orbits (Overall and nX filtered)
- Full Shaft Motion: Shaft Centerline + Clearance Circle + Orbits
- Bode, Polar and Trend Plots
- Full and Half Spectrum, Cascade and Waterfall
- Gap Voltage Reference
- Slow Roll Vector Reference for Run Out Correction
- Journal Bearing Tools: Gap Voltage Reference, Run Out Compensation.
- Record and Playback.
Turbo Machinery Vibration Analysis (Steam and Gas Turbines, Compressors), Journal Bearing Analysis
- Frequency range Analyser: 10Hz to 80kHz
- Dynamic Range of Hammer:2200n to 22200N
- Features: Portable Analyser, Suitable for finding structural behavior small and larger Structure
- Testing of structural Behavior like Damping value and Natural Frequencies.
- Noise and Vibration Measurement and Analysis.
- Onsite dynamic balancing of spindles and motors.
- Bandwidth: 15000Hz
- Max Speed:10000rpm
- Sensitivity: 80 mV/ µm and 0.4 V/ µm
- Range: 250 µm and 50 µm
- High Precision Spindle Running Accuracy Measurement and Spindle Thermal Growth Measurement
- Frequency Range: 0 Hz to 40kHz
- Features: 24 bit, 4 Channel Real Time Analyser ,1/3rd octave band Measurement, Data Recording and Analyzing
- Marine propulsion certification and maintenance , Wind turbines, gearboxes and transmissions monitoring and maintenance.
- Object Temperature Range: -200C to 6500C
- Focus: Automatic or Manual
- Accuracy:+- 20C
- Emissivity Correction : 0.01 to 1
- Image Storage: JPEG
- Measurement of heat development electrical and mechanical devices, detect blocked pipe work and insulation defects.
- Frequency Range: 0Hz to 10kHz
- Octave Band : 1/3rd Octave
- PC based Sound intensity measurement & Analysis system for Noise source Identification and ranking, Noise level contour mapping and sound power measurement.
- Frequency Range: 20Hz to 20kHz
- Dynamic Range: 130dB
- Overall Sound Pressure Level Measurement of Rotating Elements
- Frequency Range: 0 Hz to 8kHz
- Sensitivity: 0.23mV/N and 2.3mV/N
- Dynamic Range: 22200N and 2200N
- The Measurement of Natural frequencies of spindles, Motor and other sheet metal components
- Frequency Range: 3.75 Hz to 20kHz
- Sensitivity: 47.53mv/Pa
- Dynamic Range: 137dB
- Working Temperature Range: -400c to 1500C
- Sound Pressure Level Measurement of Rotating Elements.
- Frequency Range: 1Hz to 10kHz
- Sensitivity: 1000 mV/g
- Dynamic Range:+/- 50g Peak
- Working Temperature Range: -200C to 1200C
- Vibration Measurement on non-Rotating Elements for a Lower Frequency Range, Like ground Vibration Measurement